ThermIQ
  • Raw data
  • Hourly data
  • Daily data
  • Monthly data
  • Thermia
    • Overview
    • Registers
  • Settings
    • Webclient info
    • User settings
    • Logout
0Outdoor temp. C
1Indoor temp. C
2Indoor temp., decimal 0.1C
3Indoor target temp. C
4Indoor target temp., decimal 0.1C
5Supplyline temp. C
6Returnline temp. C
7Hotwater temp. C
8Brine out temp. C
9Brine in temp. C
10Cooling temp. C
11Supplyline temp., shunt C
12Electrical Current A
13
13:0Aux. heater 3 kW Boolean
13:1Aux. heater 6 kW Boolean
14Supplyline target temp. C
15Supplyline target temp., shunt C
16
16:0Brinepump Boolean
16:1Compressor Boolean
16:2Flowlinepump Boolean
16:3Hotwater production. Boolean
16:4Auxilliary 2 Boolean
16:5Shunt - Boolean
16:6Shunt + Boolean
16:7Auxilliary 1 Boolean
17
17:0Shuntgroup - Boolean
17:1Shuntgroup + Boolean
17:2Shunt cooling - Boolean
17:3Shunt cooling + Boolean
17:4Active cooling Boolean
17:5Passive cooling Boolean
17:6Alarm Boolean
18STATUS1 Units
19
19:0Alarm highpr.pressostate Boolean
19:1Alarm lowpr.pressostate Boolean
19:2Alarm motorcircuit breaker Boolean
19:3Alarm low flow brine Boolean
19:4Alarm low temp. brine Boolean
20
20:0Alarm outdoor t-sensor Boolean
20:1Alarm supplyline t-sensor Boolean
20:2Alarm returnline t-sensor Boolean
20:3Alarm hotw. t-sensor Boolean
20:4Alarm indoor t-sensor Boolean
20:5Alarm incorrect 3-phase order Boolean
20:6Alarm overheating Boolean
21DEMAND1
22DEMAND2
23Pressurepipe temp. C
24Hotw. supplyline temp. C
25Integral C*min
26Integral, reached A-limit
27Defrost *10s
28Minimum time to start min
29Program version
30Flowlinepump speed %
31Brinepump speed %
32STATUS3
 
50Indoor target temp. C
51Mode läge #
52Curve C
53Curve min C
54Curve max C
55Curve +5 C
56Curve 0 C
57Curve -5 C
58Heatstop C
59Temp. reduction C
60Room factor C
61Curve 2 C
62Curve 2 min C
63Curve 2 max C
64
65
66Outdoor stop temp. (20=-20C) C
67Pressurepipe, temp. limit C
68Hotwater starttemp. C
69Hotwater operating time min
70Heatpump operating time min
71Legionella interval days
72Legionella stop temp. C
73Integral limit A1 C*min
74Hysteresis, heatpump C
75Returnline temp., max limit C
76Minimum starting interval min
77Brinetemp., min limit (-15=OFFV) C
78Cooling, target C
79Integral limit A2 10 C*min
80Hysteresis limit, aux C
81Max step, aux # steps
82Electrical current, max limit A
83Shunt time s
84Hotwater stop temp. C
85Manual test mode mode #
86STATUS7
87Language language #
88STATUS8
89Factory settings setting #
90Reset runtime counters Boolean
91Calibration outdoor sensor C
92Calibration supplyline sensor C
93Calibration returnline sensor C
94Calibration hotwater sensor C
95Calibration brine out sensor C
96Calibration brine in sensor C
97Heating system type 0=VL 4=D type #
98
98:0Add-on phase order measurement Boolean
98:1TILL2 Boolean
98:2Add-on HGW Boolean
98:3TILL4 Boolean
98:4TILL5 Boolean
98:5TILL6 Boolean
98:6Add-on Optimum Boolean
98:7Add-on flow guard Boolean
 
99Logging time min
100Brine run-out duration 10 s
101Brine run-in duration 10 s
102Legionella peak heating enable Boolean
103Legionella peak heating duration h
104Runtime compressor h
105STATUS9
106Runtime 3 kW h
107STATUS10
108Runtime hotwater production h
109STATUS11
110Runtime passive cooling h
111STATUS12
112Runtime active cooling h
113STATUS13
114Runtime 6 kW h
115STATUS14
116STATUS15


© ThermIQ 2019